Complete the steps below to install a flush mount digital clock/timer to either a new or existing wall surface.
Qty |
|
---|---|
1 |
Flush Mount Junction Box. Material: ABS plastic, Color: black; UL listed (UL 50E 1st Ed; listing number E469550 |
4 |
#10 Phillips Flat Head Screw |
4 |
Drywall Anchors |
Clock Type |
Weight |
Max. Current Draw |
Width from Wall (A) |
Height (B) |
Depth (C) |
---|---|---|---|---|---|
2.5" (6.4 cm), 6-Digit |
2.0 lbs. (0.9 kg) |
230 mA |
16.8" (42.7 cm) |
6.5" (16.5 cm) |
3.4" (8.6 cm) |
-
Mount flush mount junction box.
New Wall Surface: mount the junction box to wall studs using four common drywall screws (not supplied). Remove the applicable conduit knockout(s) for the incoming AC power and the timer input (required for timer models only). Do not remove knockouts that you will not be using.
Existing Wall Surface: cut a 14.4 in. (36.5 cm) wide x 5.8 in.(14.7 cm) high wall opening between two wall studs. Securely mount the junction box to all studs using four common drywall screws (not supplied) at each of the corner locations. Remove the applicable conduit knockout(s) for the incoming AC power conduit and the timer input conduit (required for timer models only). Do not remove knockouts that you will not be using.
-
Connect conduit connection(s) to the junction box.
Note
For timer models only, AC wiring is required to be located to the right side of the junction box divider and the timer input to the left side.
New Wall Surface only: cut out a 14 in. (35.5 cm) wide x 5.25 in. (13.3 cm) high wall opening for placement of the clock assembly. Trim opening if necessary.
Gently snap the Flush Mount bezel onto the front of the clock/timer.
Secure wiring and complete AC power. For a timer model, connect the timer inputs.
Insert clock assembly into the wall opening.
Level clock assembly within wall opening and secure bezel to the wall surface using the four screws and anchors (supplied) at each of the corner locations.