Model: XR Series and 14000 Series Transmitters
Symptoms
All or some of the below symptoms may be present.
Transmitter front display screen is dim.
Transmitter syncs its time, cycles back to counting up, syncs its time, and then cycles again.
Cause
This may be due to a power issue.
Analyze
If power to the Transmitter power supply is bad, resolve the issue.
If it's determine the UPS (surge protector/battery backup) is defective, replace UPS and bypass until replaced.
If power to the Transmitter power supply is good, replace the power supply as the first step.
If these steps do not resolve the problem, the Transmitter may be required to be replaced.
Solution