Model: XR Transmitter and 14000 Transmitter
All or some of the below symptoms may be present.
Transmitter front display screen is dim.
Transmitter syncs its time, cycles back to counting up, syncs its time, and then cycles again.
If power to the Transmitter power supply is bad, get the issue corrected.
If it's determine the UPS (surge protector/battery backup) is defective, bypass it until is can be replaced.
If power to the Transmitter power supply is good, replace the power supply as your first step.
If these steps do not resolve the problem, the Transmitter may be required to be replaced.